Summit Air & Comfort
Customer
System details
Inspection findings
Work performed
Work completed
- Filter checked / replaced
- Coils inspected and cleaned
- Temperature split measured
- Static pressure measured
- Blower and drain pan inspected
- System cycled and verified operational
After photos

Technician notes
Performed full cooling-season service: washed the condenser coil, rinsed the evaporator, replaced the air filter, cleared and flushed the condensate drain, tested electrical components, and verified temperature split.
Run capacitor is drifting below tolerance. Condensate drain was partially blocked with biofilm.
Replace the run capacitor at the next visit to avoid a mid-summer failure. Add a drain-pan treatment tablet each season and change filters every 90 days.
Thermostat schedule reviewed with the customer; setback raised 2°F for efficiency.
Documentation record
- Report completed
- Aug 27, 2026, 4:30 PM
- Technician
- Eli Navarro
- Documented by
- Summit Air & Comfort
- Photos
- 1 attached, 1 taken in app