Old Hearth Chimney Co.
Customer
Chimney details
Inspection findings
Work performed
Work completed
- Firebox and damper inspected
- Flue swept and vacuumed
- Cap and crown inspected
- Creosote level documented
- Findings shared with customer
During photos

Technician notes
Set up containment and a HEPA vacuum, rotary-swept the full flue and smoke chamber, cleaned the firebox, cleared the cap screen, and lubricated the damper hinge.
Damper sticks partially closed when cold. Cap screen was restricting draft. Two mortar joints in the smoke chamber are eroding.
Parge the smoke chamber joints before the next burning season and replace the cap with a properly sized stainless model. Burn only seasoned hardwood.
Customer burns roughly two cords per season — annual sweep recommended.
Documentation record
- Report completed
- Aug 27, 2026, 4:30 PM
- Technician
- Grant Whitaker
- Documented by
- Old Hearth Chimney Co.
- Photos
- 1 attached, 1 taken in app